Most business at Xerox is likely to go well and generate sufficient profit. A reason for Xerox not to respond to the minority experiencing technical problems.
I bought the Xerox Workstation at the time because the brand had a good name. The reason I chose a laser printer was because I printed too little and my ink jet printer dried up every year. A laser printer does not have this problem.
After 2 years and 2 months I got the well-known 062-380 problem. I first tried to get help from the shop for repair. When the store wouldn’t help me, I asked Xerox directly for help. Xerox wanted to repair the workstation, but it cost twice the price of a new machine. Of course I’m not crazy and I didn’t do it… I’m really not mentally disturbed.
The printer itself works great. I’m still working on the supplied toner cartridges. To solve my problem I bought a small inexpensive printer/scanner from HP so that I can continue scanning.
My problem has been solved with this and as written before: NEVER AGAIN A XEROX IN MY HOUSE. Xerox is not going to help simple private users. The company is too big for that. We are not important.
NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the
Change Settings button) to check the value (diagnosis result).
Table 1 LED
Current value
Component Name
00
Not applicable (No errors)
01
LED Lamp PWB
02
CCD Lens Assembly
03
CCD Flexible Flat Cable
10
LED Lamp Flexible Flat Cable
12
IIT-ESS Video Cable
14
IIT-ESS I/O Cable
17
LVPS-IIT/Fax Power Cable (DC Harness)
4.
After replacing the appropriate parts, again change the value for NVM location [715-030]
to «1» and then execute «NVM Write».
5.
Check that the current value column becomes «000».
6.
If the problem persists after performing the above procedure, continue and check the fol-
lowing:
•
LED Lamp broken:
Component Control
•
Check the Flat Cable between the LED Lamp PWB
J723
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
Check the Flat Cable between the CCD Lens Assembly
J710
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
The coaxial cable between the IIT PWB
open circuit, short circuit, and poor contact
Initial Issue
WorkCentre 5335 Family Service Documentation
PL No.
—
PL 1.4
PL 1.2
PL 1.2
PL 1.4
PL 18.4
PL 18.4
PL 18.4
[062-002]
(PL
1.2)
P/J7001
and the IIT PWB
P/J700
and the IIT PWB
P/J7191
and the ESS PWB
P/J336
BUS Updated 12/2011
BSD-ON:
BSD 6.1 — Document Illumination
BSD-ON:
BSD 6.6 — Image Input
Insufficient lamp brightness was detected when performing AGC.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Initial Actions
Check the light path for any obstacle, and the lamp, the lens, the mirror and the White Correct-
ing Plate for deterioration or contamination.
Procedure
1.
Turn the power ON and enter the Diag mode. Change the value for NVM location [715-
030] to «1» and then execute «NVM Write».
2.
A 3 or 4-digit number is displayed in the current value column.
3.
Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace
the appropriate parts.
Sample Display
•
110 (3-digit display):
P/
LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor
contact.
P/
(The first digit «1» in «110» is the upper digit, which indicates the LED Lamp PWB («0»
in «01» is not displayed). The lower 2 digits «10» indicates the LED Lamp Flexible Flat
Cable.)
for
•
1000 (4-digit display):
The LED Lamp Flexible Flat Cable is damaged or has poor contact.
(The first 2 digits «10» in «1000» are the upper digits, which indicates the LED Lamp
Flexible Flat Cable. The lower 2 digits «00» indicates that nothing is applicable (no
failures).)
07/2011
2-779
Status Indicator RAPs
062-371, 062-380
-
10-22-2021
#1
WorkCenter 6515, error 062-380
Hello Companions.
First to say that I do not handle this brand (I am a ricoh technician/distributor), it is a request from a customer, who has a Xerox WorkCenter 6515, and asks my technical department if we can solve this problem.
The device throws this fault code «062-380» so it does not allow you to operate, someone can lend a hand. Thank you.
Apologies for my English, it’s not my mother tongue and I’m helping the translator.
ALL WILL BE WELL
-
10-22-2021
#2
Re: WorkCenter 6515, error 062-380
Insufficient lamp brightness was detected when performing AGC.
-
10-25-2021
#3
Re: WorkCenter 6515, error 062-380
Originally Posted by adriansto
Se detect� un brillo insuficiente de la l�mpara al realizar AGC.
I understand that this failure may be due to the explorer’s lamp being dirty, or it being melted/broken.
True? In the case of dirt, it should be possible to clean both the lamp and the mirrors of the explorer.
You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.
Last edited by UNICORNico; 10-25-2021 at 04:09 PM.
Apologies for my English, it’s not my mother tongue and I’m helping the translator.
ALL WILL BE WELL
-
10-25-2021
#4
Re: WorkCenter 6515, error 062-380
[QUOTE=UNICORNico;1945975]
Originally Posted by adriansto
You could confirm this to me, or it’s another lamp and I’m getting confused. Thank you.
It is about scanner lamp. Under the scanner glass it is white band ( label ) Check that label is clean, check if the scanner mirrors are clean. All of these works on AGC = Automatic Gain Control
-
10-25-2021
#5
Junior Member
- Rep Power
- 0
Re: WorkCenter 6515, error 062-380
You have to replace the IIT assy , ie the scanner assy below is description of the fault ,
062-311, 313, 321, 360, 371, 380, 386, 389, 393, 396-398 IIT
Fail RAP
062-311 Error detected in IISS software.
062-313 Unexecutable Scan command error.
062-321 Unexecutable Scan command error.
062-360 Carriage home position error is detected.
062-371 IIT failure Lamp error is detected.
062-380 Insufficient lamp brightness was detected when performing AGC.
062-386 During AOC (darkness adjustment), detected CCD output error.
062-389 Overrunning of CRG was detected.
062-393 CISASIC communication error is detected.
062-396 Connection problem of CIS flat cable was detected.
062-397 Connection problem of ESS Video cable was detected.
062-398 Connection problem of ESS I/O cable was detected.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to [GP 4]. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
1. Power the machine down then back up, [GP 4], the error persists,
2. Clean the scanner platen and the white stripe, [GP 34], the error persists,
3. Install a new IIT Assembly, [REP 50.1.2], the error persists,
4. Install a new DADF Assembly, [REP 50.1.1],
Модератор: vetal
-
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4
- 5
- 5710
3100
Пн ноя 18, 2019 8:24 pm
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
-
-
Xerox WC 3119: «Замятие 1»
kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4
- 22
- 39539
kokubenko
Ср ноя 23, 2011 4:47 pm
-
Xerox WC 3119: «Замятие 1»
-
-
Xerox WC3220 — Ложное замятие бумаги, Замятие 0
Romeo в форуме Принтеры, МФУ, факсы, копиры формата A4
- 25
- 11320
Romeo
Пн окт 12, 2020 7:13 pm
-
Xerox WC3220 — Ложное замятие бумаги, Замятие 0
-
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
Володья в форуме Принтеры, МФУ, факсы, копиры формата A4
- 8
- 12989
Володья
Сб апр 30, 2011 8:05 am
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
-
-
Xerox WC 3119 без признаков «жизни»
MorZ в форуме Принтеры, МФУ, факсы, копиры формата A4
- 5
- 6931
Goldwater
Чт окт 08, 2020 11:34 pm
-
Xerox WC 3119 без признаков «жизни»
Вернуться в Принтеры, МФУ, факсы, копиры формата A4
Кто сейчас на форуме
Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 43
12.12.2011
Вопрос:
Здравствуйте. Есть аппарат Xerox WorkCentre Pro 128.
Последнее время часто стала появляться ошибка 062-380, помогает перезагрузка (по питанию), но иногда это необходимо сделать раз 5-10. Ошибка появляется в основном, когда МФУ выходит из режима safemode. Что это может быть и как с этим бороться?
p.s. зеркала визуально чистые
Ответ:
062-380 — неисправность в блоке сканера. Нужно проверить лампу, объектив, зеркало. Обратитесь в сервисный центр.